Best Team Award Winning giant project
"Multi Purpose Water Treatment Pilot Plant"
Project Album
Project Video
PACE Expo Album
PACE 2011 - DACCT - KU
Shield of BEST TEAM WORK awarded by Pro Vice Chancelor, University of Karachi, Dr. Shahana Urooj Kazmi and Chairman of DACCT , Dr. Mehdi Hassan Kazmi for the biggest team of Multi Unit Giant Project of Multi Purpose Water Treatment Pilot Plant (PACE 2011, DACCT - KU) |
Projects Expo entrance, Water treatment Plant is located in-front of entrance |
Project Supervisor:
Facebook Page: (Applied Scientists and Engineers Page)
https://www.facebook.com/pages/Applied-Scientists-and-Engineers-Page/128020013901973?fref=ts
https://www.facebook.com/pages/Applied-Scientists-and-Engineers-Page/128020013901973?fref=ts
Asst. Supervisors;
Rafay Ibad and Farhaj Qureshi
Team Members:
Numair Khan , Mirza Wajid Baig , Syed Taha Sha , Ahsan Khatri , Mohammed Hadi Kirmani , Sheikh Humayoun Farid , Maaz ur Rehman , Abdul Azeem Asad
PACE 2011 (1st Day) - Best Team Award by Pro Vice Chancellor of KU Dr. Shahana Urooj Kazmi and Chairman DACCT Dr. Mehdi Hassan Kazmi (All Group Members received this award) |
Certificate Ceremony (2nd Day) - Project Certificates received from Manager Artistic Textiles. |
Objective of Project:
To produce multi purpose purified and treated water from Industrial Waster Water in order to meet the requisite of Industrial Pollution Abatement.Team Members |
Plant Units:
Brief information about the units involved in this multi unit giant project presented by 11 members, discussed earlier, Eight units were connected in different loops of project for different process, the main processes involved are DI Water production, Mineral Water, Distilled Water, Depyrogenated filtered Water, Air Handling Unit (AHU) with HEPA filteration and HVAC support system for particulate free high quality fresh and conditioned air, all possible means utilized for Air and Water pollution abatement and complete looping of all units to minimize energy loses to maximum possible extent, the units installed for this purpose are given below;
Project video is available at
1) - Filtration;
Sand filter, Activated Carbon (Granular), Depyrogenation by UV Light, Poly Proplene filter. (Flow under Gravity)2) - Deionization Unit;
Double bed Ion Exchanger used to reduce the conductivity due to contaminations/salts/ions upto 4 micro seimens.3) - Distillation Unit:
Steam generator with water tube boiler mechanism and Centrifugal pump (Head provided by pump)4) - Heat Exchanger:
Parallel flow heat Exchanger to liquefy the steam from Boiler.5) - Baffled Mineral Shaker:
To produce mineral water by mixing stoichiometrically desired quantity of minerals with simultaneous action of Turbine-Baffles system.6) - Double Stage Cooling Tower:
To lower the temperature of treated water to standard temperature, equipped with electrical panel and process analyzer.7) - 3 Coil Brine Chiller:
To produce Chill water for Air Handling Unit and Air Conditioning.8) - Air Handling Unit:
Equipped with HEPA (High efficiency particulate air) filtration system, Bag filters, blowers and refrigeration coil for complete air conditioning process.Project Feasibility, Productivity and Cost Effectiveness:
This plant can produce Deionized water, Filtered water, Mineral water, Distilled Water without using multiple effect water still and RO Plant, also without adding the cost of lithium bromide (LiBr) absorption chiller as the combined effect of Units 4, 6 & 7 (i.e, Parallel flow Heat Exchanger, Double Stage Cooling Tower and 3 Coil Brine Chiller) is adequate and sufficient to approach the desired temperature, also the piping from boiler to Cooling Tower is made from conducting material which itself reduces temperature like closed systems energy exchange, insulating material in piping is used between Cooling tower and the last unit.
The project is based on very simple processes, also it can be initiated with a very low budget of approximately 100,000/=Rs. filters are also cheap contrary to RO membrane which is too costly.
Documentary Link:
1) - DACCT Documentary, University of Karachi2) - https://www.facebook.com/video/video.php?v=393564890679973&saved
3) - https://www.facebook.com/video/video.php?v=560102947352101&saved
This Documentary is the first official documentary of the Department of Applied Chemistry and Chemical Technology, made by Event Media Manager for Projects Expo PACE 2011, SAAD ABDUL WAHAB and his team media team members Bilal (Equipment provider), Saulat (Camera Man), Farhaj (Assistant), Huzaifa (Still Photographer) and Hassan Ali (Technical Assistant).
PACE ALBUM
Inauguration of PACE 2011 by Senator Haseeb Khan |
Chief Guest of PACE (1st day) Senator Haider Abbas Rizvi addressing the participants of projects Expo PACE 2011, Chairman of DACCT, PVC-KU, and DACCT Faculty members also present on stage. |
Entrance of Projects Expo PACE 2011 |
Interview of Project supervisor Saad Abdul Wahab |
Senator Haseeb Khan asking about Project - Briefing by Taha Sha |
Certificate of Event Media Manager awarded to Saad Abdul Wahab by Chairman Dr.Mehdi Hassan Kazmi |
More than 30 projects were included in Projects Expo PACE 2011 |
Group photo of PACE 2011 Organizers with Chairman DACCT, Chief Organizer and Media manager |
Multi Purpose Water Treatment Pilot Plant (PACE 2011) |
Saad Abdul Wahab comparing in Certificates Distribution Ceremony while Dr.Mehdi awarding Certificate of participation to Madam Afsheen Fatima |
Documentary presentation time |
Shield of Media Manager awarded to Saad Abdul Wahab by Pro Vice Chancellor Dr. Shahana Urooj Kazmi and Chairman Dr. Mehdi Hassan Kazmi (Dr. Ishrat Ex-Chairman DACCT, Dr.Ashraf Kamal and Prof.A.Rasheed sitting behind at stage) |
Chief Guest of Certificates distribution ceremony "Anjum Rifatullah Khan" Country Manager of MOBIL ASKARI LUBRICANTS (MAL Pakistan) |
Media Manager Saad Abdul Wahab with Chief Organizer PACE Madam Unber Shakeel, Chairman of Applied Chemistry & Chemical Technology Department Dr.Mehdi Hassan Kazmi and Pro Vice Chancellor Dr. Shahana Urooj Kazmi |
Senator Haseeb Khan and Pro Vice Chancellor of Karachi University, Dr.Shahana Urooj Kazmi visiting Multi Purpose Water Treatment Pilot Plant's Air Handling Unit with Project Supervisor Saad Abdul Wahab |
Sir Kashif Riaz receiving certificate from Chairman DACCT |
Media Manager with Chief Organizer Unber Shakeel |
Project briefing to the guests of Expo. |
Event Media Manager and Project Supervisor Saad Abdul Wahab with Chief Organizer PACE 2011 Madam Unber Shakeel and Asst.Supervisor Farhaj Qureshi |
Pilot Plant Project Supervisor Saad Abdul Wahab with all team members of Multi Purpose Water Treatment Pilot Plant after receiving Best Team Award by PVC - KU and Chairman DACCT |
Asst.Supervisor of Pilot Plant Project Rafay Ibad at Project stall. |
Shield of Event Media Manager PACE 2011 |
A group member Numair Khan |
SAMPLE QUALITY
We analyses the
samples of drinking water and perform tests which conclude that all samples are
differs in their characteristic properties but finally qualifies as drinking
water. These Properties create difference in quality of water. A brief
description on each prperty is given below:
pH
S.No
|
Water Sample
|
Observed pH
|
Actual pH
|
1.
|
Nestle
|
8.41
|
6.5
– 8.5
|
2.
|
Spring
|
6.42
|
7
– 3
|
3.
|
Aquafina
|
8.28
|
6.5
– 8.5
|
pH value determines whether water is hard or
soft. The pH of pure water is 7.The normal range for pH in surface water
systems is 6.5 to 8.5 and for groundwater systems 6 to 8.5.water with a low pH
(< 6.5) could be acidic, soft, and corrosive. Therefore, the water could
contain metal ions such as iron, manganese, copper, lead, and zinc...or, on
other words, elevated levels of toxic metals. This can cause premature damage
to metal piping, and have associated aesthetic problems such as a metallic or
sour taste, staining of laundry, and the characteristic "blue-green" staining of sinks and drains.
More importantly, there are health risks associated with these toxins. Water
with a pH > 8.5 could indicate that the water is hard. Hard water does not
pose a health risk, but can cause aesthetic problems. These problems include an
alkali taste to the water (making that morning coffee taste bitter!), formation
of a deposit on dishes, utensils, and laundry basins, difficulty in getting
soaps and detergents to lather, and formation of insoluble precipitates on
clothing.
Result
The ph range of nestle and aquafina is in the required limit while the ph of spring is not in the required limit.
Chloride Content
S.No
|
Water Sample
|
Observed Chloride content (mg Cl / L)
|
Actual Chloride content (mg Cl / L)
|
1.
|
Nestle
|
54.98
|
77
- 150
|
2.
|
Spring
|
29.9
|
38
|
3.
|
Aquafina
|
4.99
|
20
|
chloride
presents a pretty good problem in large concentrations, giving water that
briny, brackish taste that would make anybody's tongue cringe in distaste.
Usually chloride concentrations found in water supplies are low, which is a
good thing since low to moderate chloride concentrations can add a pleasant
taste to your drinking water, making chloride desirable for this particular
reason, while high concentrations of chloride ions can add to the electrical
conductivity of the water EPA Secondary Drinking Water Regulations
recommended the maximum concentration of 250mg/1 for chloride ions.we don’t
need as much chloride because of the regular intake of Nacl so chloride content
should be less in the water.
Result
On the
basis of above theory all the chloride value of the sample is in the acceptable
range. But it is good that chloride content should be in moderate range to have
a good taste so spring is good as compare to others.
Hardness
Serial number
|
Sample
|
Observed Calcium hardness (mg
CaCO3 / L)
|
ActualCalcium hardness (mg CaCO3 / L)
|
1.
|
Nestle
|
120
|
40
- 70
|
2.
|
Spring
|
50
|
Not
mention
|
3.
|
Aquafina
|
120
|
54
|
Hard water is not a health
hazard. In fact, the National Research Council (National Academy of Sciences)
states that hard drinking water generally contributes a small amount toward
total calcium and magnesium human dietary needs. They further state that in some
instances, where dissolved calcium and magnesium are very high, water could be
a major contributor of calcium and magnesium to the diet.
Result
On the basis of above we can
conclude that nestle is good because of high range of hardness.
Total Dissolved Solid
S.No
|
Samples
|
Observed T.D.S. mg/L
|
Actual T.D.S.
mg/L
|
1.
|
Nestle
|
110
|
160 - 350
|
2.
|
Spring
|
120
|
259.7
|
3.
|
Aquafina
|
120
|
105
|
The electrically
charged dissolved particles make ordinary natural water a good conductor of
electricity. Coversely, pure water has a high electrical resistance, and
resistance is frequently used as a measure of its purity.
Since only a few
of these most common ionic water contaminants are health related, most natural
water supplies are safe to drink from the standpoint of dissolved inorganic
chemical contaminants. However, even though found more rarely -- and in much
smaller quantities -- certain inorganic ions can be toxic.
Result
So on the basis of
above description it can be concluded that we can be concluded which one is
better in them after knowing the complete information of these electric charge
dissolved in it. But to have a low limit of tds is so aquafina is good because
of having low tds content.
Sulphate
Content
S.No
|
Sample
|
Observed Sulphate Content
mg SO4/L
|
Actual Sulphate Content mg SO4/L
|
1.
|
Nestle
|
11.6
|
7-30
|
2.
|
Spring
|
11.5
|
59
|
3.
|
Aquafina
|
12.3
|
52
|
Ø High amounts of
various sulphate salts may give drinking water an offensive taste. Depending
upon the type of sulphate salt present in the water, most people begin to
notice an offensive taste at concentrations ranging from 250 to 1,000 mg/L.
Ø High
concentrations of sulphate may interfere in the efficiency of chlorination in
some water supplies.
Ø Also, sulphate
salts may increase the corrosive properties of water.
Ø Air may contain sulfates in areas of heavy
industry. Many sulfate salts can react in air to form dilute acid, which can
irritate intestinal pain
Ø dehydration as a result of diarrhea
Ø slight decrease in normal stomach
acidic nestle is best because of low content of sulfate
Result
Nestle
is best because of low content of sulfate
Alkalinity
S.No
|
Sample
|
Observed
Total Alkalinity
(meq/Lit)
|
1.
|
Nestle
|
60
|
2.
|
Spring
|
150
|
3.
|
Aquafina
|
60
|
Alkalinity of
water may be due to the presence of one or more of a number of ions. These
include hydroxides, carbonates and bicarbonates. Small amounts of carbonates
are found in natural water supplies in certain sections of the country, rarely
exceeding 3 or 4 gpg. Bicarbonates are the most common sources of alkalinity.
Almost all natural supplies have a measurable amount of this ion, ranging from
0 to about 50 gpg. Phosphates and silicates are rarely found in natural
supplies in concentrations significant in the home. Moderate concentrations of
alkalinity are desirable in most water supplies to balance the corrosive
effects of acidity. However, excesive quantities cause a number of problems.
These ions are, of course, free in the water, but have their counterpart in
cations such as calcium, magnesium and sodium or potassium.You probably will not notice
an alkaline condition due to bicarbonate ions except when present in large
amounts. In contrast, you should readily detect alkalinity due even to fairly
small amounts of carbonate and hydroxide ions.
Strongly alkaline
Waters have an objectionable "soda" taste. The EPA Secondary Drinking
Water Regulations limit alkalinity only in terms of total dissolved solids (500
ppm) and to some extent by the limitation on pH.
Highly mineralized
alkaline waters also cause excessive drying of the skin due to the fact that
they tend to remove normal skin oils.
RESULT
On the basis of
description we can conclude that the spring and aquafina are comparativele good
compare to nestle because nestle contain high alkalinity.
The Overall Results Of Water
Analysis:
water treatment
|
ph
|
Chlorides (mg/L)
|
Hardness (mg/L)
|
TDS (mg/L)
|
Alkanity (mg/L)
|
Sulphate (mg/L)
|
Nestle
|
8.41
|
54.98
|
120
|
110
|
60
|
11.6
|
Spring
|
6.42
|
29.9
|
50
|
120
|
150
|
11.5
|
Aquafina
|
8.28
|
4.99
|
120
|
120
|
60
|
12.3
|
Sources Of Error
There are several sources of error due to which our results
are deviated from the standards result
The apparatus are calliberated at 25 centigrade
For washing we use distilled water which already contain
many impurities
Apparatus is not properly washed
Any chromic acid content remain after washing causing the
error in result
The concentration of reagent may be changed due to prolonged
storage
Some time colour changed was not sharped they can also
effect on the readind
Human error
DISCUSSION
pH:
The concept of pH was first introduced by Danish chemist Søren Peder Lauritz Sørensen at the Carlsberg Laboratory in 1909. It is unknown what the exact definition of p is. Some references suggest the p stands for “Power”, others refer to the German word “Potenz” (meaning power in German), still others refer to “potential”. Jens Norby published a paper in 2000 arguing that p is a constant and stands for “negative logarithm”; which has also been used in other works. H stands for Hydrogen. Sørensen suggested the notation "PH" for convenience, standing for "power of hydrogen", using the cologarithm of the concentration of hydrogen ions in solution, p[H] Although this definition has been superseded p[H] can be measured if an electrode is calibrated with solution of known hydrogen ion concentration.
Pure water is said to be neutral. The pH for pure water at 25 °C (77 °F) is close to 7.0. Solutions with a pH less than 7 are said to be acidic and solutions with a pH greater than 7 are said to be basic or alkaline. pH measurements are important in medicine, biology, chemistry, food science, environmental science, oceanography and many other applications.
pH is defined as minus the decimal logarithm of the hydrogen ion activity in an aqueous solution. By virtue of its logarithmic nature, pH is a dimensionless quantity.
pOH
pOH is sometimes used as a measure of the concentration of hydroxide ions, OH−, or alkalinity. pOH is not measured independently, but is derived from pH. The concentration of hydroxide ions in water is related to the concentration of hydrogen ions by [OH−] = KW /[H+]where KW is the self-ionisation constant of water. Taking cologarithms
pOH = pKW − pH.
So, at room temperature pOH ≈ 14 − pH. However this relationship is not
strictly valid in other circumstances, such as in measurements of soil
alkalinity.Total dissolved solids:
Total Dissolved Solids (often abbreviated TDS) is an expression for the combined content of all inorganic and organic substances contained in a liquid which are present in a molecular, ionized or micro-granular (colloidal sol) suspended form. Generally the operational definition is that the solids must be small enough to survive filtration through a sieve size of two micrometres. Total dissolved solids are normally only discussed for freshwater systems, since salinity comprises some of the ions constituting the definition of TDS. The principal application of TDS is in the study of water quality for streams, rivers and lakes, although TDS is generally considered not as a primary pollutant (e.g. it is not deemed to be associated with health effects), but it is rather used as an indication of aesthetic characteristics of drinking water and as an aggregate indicator of presence of a broad array of chemical contaminants.Primary sources for TDS in receiving waters are agricultural runoff, leaching of soil contamination and point source water pollution discharge from industrial or sewage treatment plants. The most common chemical constituents are calcium, phosphates, nitrates, sodium, potassium and chloride, which are found in nutrient runoff, general stormwater runoff and runoff from snowy climates where road de-icing salts are applied. The chemicals may be cations, anions, molecules or agglomerations on the order of 1000 or fewer molecules, so long as a soluble micro-granule is formed. More exotic and harmful elements of TDS are pesticides arising from surface runoff. Certain naturally occurring total dissolved solids arise from the weathering and dissolution of rocks and soils. The United States has established a secondary water quality standard of 500 mg/l to provide for palatability of drinking water.
Total dissolved solids are differentiated from total suspended solids (TSS), in that the latter cannot pass through a sieve of two micrometres and yet are indefinitely suspended in solution. The term "settleable solids" refers to material of any size that will not remain suspended or dissolved in a holding tank not subject to motion, and exclude both TDS and TSS. Settleable solids may include larger particulate matter or insoluble molecules.
Measurement of TDS:
The two principal methods of measuring total dissolved solids are gravimetry and electrical conductivity. Gravimetric methods are the most accurate and involve evaporating the liquid solvent to leave a residue which can subsequently be weighed with a precision analytical balance (normally capable of .0001 gram accuracy). This method is generally the best, although it is time consuming and leads to inaccuracies if a high proportion of the TDS consists of low boiling point organic chemicals, which will evaporate along with the water. In the most common circumstances inorganic salts comprise the great majority of TDS, and gravimetric methods are appropriate.Electrical conductivity of water is directly related to the concentration of dissolved ionized solids in the water. Ions from the dissolved solids in water create the ability for that water to conduct an electrical current, which can be measured using a conventional conductivity meter or TDS meter. When correlated with laboratory TDS measurements, electrical conductivity provides an approximate value for the TDS concentration, usually to within ten percent accuracy.
Hard water:
Hard water is water that has high mineral content (mainly calcium and magnesium ions) (in contrast with soft water). Hard water minerals primarily consist of calcium (Ca2+), and magnesium (Mg2+) metal cations, and sometimes other dissolved compounds such as bicarbonates and sulfates. Calcium usually enters the water as either calcium carbonate (CaCO3), in the form of limestone and chalk, or calcium sulfate (CaSO4), in the form of other mineral deposits. The predominant source of magnesium is dolomite (CaMg(CO3)2). Hard water is generally not harmful to one's health.The simplest way to determine the hardness of water is the lather/froth test: soap or toothpaste, when agitated, lathers easily in soft water but not in hard water. More exact measurements of hardness can be obtained through a wet titration. The total water 'hardness' (including both Ca2+ and Mg2+ ions) is read as parts per million (ppm) or weight/volume (mg/L) of calcium carbonate (CaCO3) in the water. Although water hardness usually only measures the total concentrations of calcium and magnesium (the two most prevalent, divalent metal ions), iron, aluminium, and manganese may also be present at elevated levels in some geographical locations.
Types of hard water
In the 1960s, scientist Chris Gilby Jnr discovered that hard water can be categorized by the ions found in the water.[citation needed] A distinction is also made between 'temporary' and 'permanent' hard water.Temporary hardness
Temporary hardness is caused by a combination of calcium ions and bicarbonate ions in the water. It can be removed by boiling the water or by the addition of lime (calcium hydroxide). Boiling promotes the formation of carbonate from the bicarbonate and precipitates calcium carbonate out of solution, leaving water that is softer upon cooling.The following is the equilibrium reaction when calcium carbonate (CaCO3) is dissolved in water:
CaCO3(s) + H2CO3(aq) ⇋ Ca2+(aq) + 2HCO3-(aq)
Upon heating, less CO2 is able to dissolve into the water (see Solubility). Since there is not enough CO2 around, the reaction cannot proceed from left to right, and therefore the CaCO3 will not dissolve as rapidly. Instead, the reaction is forced to the left (i.e. products to reactants) to re-establish equilibrium, and solid CaCO3 is formed. Boiling the water will remove hardness as long as the solid CaCO3 that precipitates out is removed. After cooling, if enough time passes the water will pick up CO2 from the air and the reaction will again proceed from left to right, allowing the CaCO3 to "re-dissolve" into the water.
For more information on the solubility of calcium carbonate in water and how it is affected by atmospheric carbon dioxide, see calcium carbonate.
Permanent hardness
Permanent hardness is hardness (mineral content) that cannot be removed by boiling. It is usually caused by the presence of calcium and magnesium sulfates and/or chlorides in the water, which become more soluble as the temperature rises. Despite the name, permanent hardness can be removed using a water softener or ion exchange column, where the calcium and magnesium ions are exchanged with the sodium ions in the column.Hard water causes scaling, which is the left over mineral deposits that are formed after the hard water had evaporated. This is also known as limescale. The scale can clog pipes, ruin water heaters, coat the insides of tea and coffee pots, and decrease the life of toilet flushing units.
Similarly, insoluble salt residues that remain in hair after shampooing with hard water tend to leave hair rougher and harder to untangle.
In industrial settings, water hardness must be constantly monitored to avoid costly breakdowns in boilers, cooling towers, and other equipment that comes in contact with water. Hardness is controlled by the addition of chemicals and by large-scale softening with zeolite and ion exchange resins.
Softening
It is often desirable to soften hard water, as it does not readily form lather with soap. Soap is wasted when trying to form lather, and in the process, scum forms. Hard water may be treated to reduce the effects of scaling and to make it more suitable for laundry and bathing.Process
A water softener, like a fabric softener, works on the principle of cation or ion exchange in which ions of the hardness minerals are exchanged for sodium or potassium ions, effectively reducing the concentration of hardness minerals to tolerable levels and thus making the water softer and giving it a smoother feelingThe most economical way to soften household water is with an ion exchange water softener. This unit uses sodium chloride (table salt) to recharge beads made of the ion exchange resins that exchange hardness mineral ions for sodium ions. Artificial or natural zeolites can also be used. As the hard water passes through and around the beads, the hardness mineral ions are preferentially absorbed, displacing the sodium ions. This process is called ion exchange. When the bead or sodium zeolite has a low concentration of sodium ions left, it is exhausted, and can no longer soften water. The resin is recharged by flushing (often back-flushing) with saltwater. The high excess concentration of sodium ions alter the equilibrium between the ions in solution and the ions held on the surface of the resin, resulting in replacement of the hardness mineral ions on the resin or zeolite with sodium ions. The resulting saltwater and mineral ion solution is then rinsed away, and the resin is ready to start the process all over again. This cycle can be repeated many times.
The discharge of brine water during this regeneration process has been banned in some jurisdictions due to concerns about the environmental impact of the discharged sodium.
Potassium chloride (softener salt substitute) may also be used to regenerate the resin beads. It exchanges the hardness ions for potassium. It also will exchange naturally occurring sodium for potassium resulting in sodium-free soft water.
Some softening processes in industry use the same method, but on a much larger scale. These methods create an enormous amount of salty water that is costly to treat and dispose of.
Temporary hardness, caused by hydrogen carbonate (or bicarbonate) ions, can be removed by boiling. For example, calcium bicarbonate, often present in temporary hard water, may be boiled in a kettle to remove the hardness. In the process, a scale forms on the inside of the kettle in a process known as "furring". This scale is composed of calcium carbonate.
Ca(HCO3)2 → CaCO3 + CO2 + H2O
Hardness can also be reduced with a lime-soda ash treatment. This process, developed by Thomas Clark in 1841, involves the addition of slaked lime (calcium hydroxide — Ca(OH)2) to a hard water supply to convert the hydrogen carbonate hardness to carbonate, which precipitates and can be removed by filtration:
Ca(HCO3)2 + Ca(OH)2 → 2CaCO3 + 2H2O
The addition of sodium carbonate also permanently softens hard water containing calcium sulfate, as the calcium ions form calcium carbonate which precipitates out and sodium sulfate is formed which is soluble. The calcium carbonate that is formed sinks to the bottom. Sodium sulfate has no effect on the hardness of water.
Na2CO3 + CaSO4 → Na2SO4 + CaCO3
Alkalinity:
Alkalinity or AT is a measure of the ability of a solution to neutralize acids to the equivalence point of carbonate or bicarbonate. Alkalinity is closely related to the acid neutralizing capacity (ANC) of a solution and ANC is often incorrectly used to refer to alkalinity. The alkalinity is equal to the stoichiometric sum of the bases in solution. In the natural environment carbonate alkalinity tends to make up most of the total alkalinity due to the common occurrence and dissolution of carbonate rocks and presence of carbon dioxide in the atmosphere. Other common natural components that can contribute to alkalinity include borate, hydroxide, phosphate, silicate, nitrate, dissolved ammonia, the conjugate bases of some organic acids and sulfide. Solutions produced in a laboratory may contain a virtually limitless number of bases that contribute to alkalinity. Alkalinity is usually given in the unit mEq/L (milliequivalent per liter). Commercially, as in the pool industry, alkalinity might also be given in the unit ppm or parts per million.Alkalinity is sometimes incorrectly used interchangeably with basicity. For example, the pH of a solution can be lowered by the addition of CO2. This will reduce the basicity; however, the alkalinity will remain unchanged.
References
- ^ "The Measurement of pH - Definition, Standards and Procedures – Report of the Working Party on pH, IUPAC Provisional Recommendation"]. 2001. http://www.iupac.org/reports/provisional/abstract01/rondinini_prs.pdf. A proposal to revise the current IUPAC 1985 and ISO 31-8 definition of pH.
- ^ a b c Carlsberg Group Company History Page, http://www.carlsberggroup.com/Company/Research/Pages/pHValue.aspx
- ^ University of Waterloo - The pH Scale, http://www.science.uwaterloo.ca/~cchieh/cact/c123/ph.html
- ^ Nørby, Jens. 2000. The origin and the meaning of the little p in pH. Trends in the Biochemical Sciences 25:36-37., http://download.cell.com/trends/biochemical-sciences/pdf/PIIS0968000499015170.pdf
- ^ Fundamentals of Analytical Toxicology, http://books.google.com.br/books?id=LBag6XlAJY0C
- ^ Sørensen, http://www.geocities.com/bioelectrochemistry/sorensen.htm
- ^ "pH". IUPAC Goldbook. http://goldbook.iupac.org/P04524.html.
- ^ Quantities and units – Part 8: Physical chemistry and molecular physics, Annex C (normative): pH. International Organization for Standardization, 1992.
- ^ Definitions of pH scales, standard reference values, measurement of pH, and related terminology. Pure Appl. Chem. (1985), 57, pp 531–542.
- ^ Nordstrom, DK et al (2000) Negative pH and extremely acidic mine waters from Iron Mountain California. Environ Sci Technol,34, 254-258.
- ^ DeZuane, John (1997). Handbook of Drinking Water Quality (2nd edition ed.). John Wiley and Sons. ISBN 0-471-28789-X.
- ^ a b C.M. Hogan, Marc Papineau et al. Development of a dynamic water quality simulation model for the Truckee River, Earth Metrics Inc., Environmental Protection Agency Technology Series, Washington D.C. (1987)
- ^ USEPA. 1991. Guidance for water quality-based decisions: The TMDL process. EPA 440/4-91-001. U.S. Environmental Protection Agency, Office of Water, Washington, DC. ^ Boyd, Claude E. (1999). Water Quality: An Introduction. The Netherlands: Kluwer Academic Publishers Group. ISBN 0-7923-7853-9.
- Holmes-Farley, Randy. "Chemistry and the Aquarium," Advanced Aquarist's Online Magazine. Alkalinity as it pertains to salt-water aquariums.
- DOE (1994) ","Handbook of methods for the analysis of the various parameters of the carbon dioxide system in sea water. Version 2, A. G. Dickson & C. Goyet, eds. ORNL/CDIAC-74.
Hey,Thanks for sharing this informative post.Water Treatment Pilot PlantsSystems We have produced water treatment pilot plants for testing applications using Reverse Osmosis, Ultrafiltration, Nanofiltration, or Microfiltration technology for testing applications such as medical, pharmaceutical, USP, dairy, electro-coat paint, and more.
ReplyDelete